Home       


 

Units for solvent recycling


Technical data and product range

Each unit is developed, planned, constructed and installed acording to your wishes and requirements.

Prices are available on request.
In our download-area you will find the brochure "Solvent recycling".

Design model   SRU-30 SRU-60 SRU-95 SRU-165 SRU-265
Overall Capacity (l) 30 60 95 165 265
Operating capacity
min.-max. (l)
15-20 30-35 50-55 90-100 150-170
Nominal distillation rate (l/h) (1) 3-10 10-25 20-40 30-65 40-90
Process pressure -1,0 to +0,5 bar 
Process temperatur (2) max. 200 °C 
Thermal oil heating integrated 
Protection class 

Ex II 1/2G EEx cdemn (ia/ib) IIA T3

Power consumption,
normal operation (kW)
1,8 2,9 5,0 8,0 11,0
Power consumption,
heating (kW)
3,0 5,0 7,5 10,0 18,0
Voltage, frequency (3) 400 V, 3 Ph, 50 Hz
Cooling medium
requirements (m³) (7)
0,6 0,7 0,9 1,0 1,2
Width (mm) 500 590 750 850
Height (mm) (4) 800-1620 1620-1650   1650-1800
Depth (mm) 1200 1500 1800 2000
Net weight approx. (kg) 180 280 380 420 540
Integrated vacuum units DT-6 DT-10  DT-30
Vacuum pressure
max. (mbar) (5)
60 60 40
Max. suction capacity m³/h (6) 6 10 25
Weight approx. (kg) 40 50 65

  (1) depending on solvent & degree of polution
  (2) elevated temperature possible
  (3) more on request
  (4) depending on residue vessel
  (5) Vacuum systems down to max. 1mbar possible
  (6) Process fluid H20 at 15°C at 50Hz
  (7) bei max. 15°C

 
Design model   SRU-450 SRU-650 SRU-1500 SRU-2000/ SRU-3000
Overall Capacity (l) 450 650 1500 2000/ 3000
Operating capacity
min.-max. (l)
250-350 350-450 1000-1200 1200-1500/ 1800-2200
Nominal distillation rate (l/h) (1) 60-160 80-200 200-500 300-600/ 400-900
Process pressure -1,0 to +0,5 bar 
Process temperatur (2) max. 200 °C 
Thermal oil heating integrated  assimilable/ separate 
Protection class 

Ex II 1/2G EEx cdemn (ia/ib) IIA T3

Power consumption,
normal operation (kW)
16,0 26,0 39,0 44/ 55
Power consumption,
heating (kW)
30 40 70 80/ 100
Voltage, frequency (3) 400 V, 3 Ph, 50 Hz
Cooling medium
requirements (m³) (7)
1,5 1,5 2,0 2,2/ 2,5
Width (mm) 2400 2800 2800 2800/ 3200
Height (mm) (4) 2800-3000 3250-3400 3800-4000 4000-4200/ 4600-4800
Depth (mm) 1600 1700 1700/ 2000
Net weight approx. (kg) 1100 1300 1600 1800/ 2100
Integrated vacuum units DT-50 DT-95 DT-110/ DT-130
Vacuum pressure
max. (mbar) (5)
40
Max. suction capacity m³/h (6) 50 80 100/ 110
Weight approx. (kg) 100 140 165/ 180

  (1) depending on solvent & degree of polution
  (2) elevated temperature possible
  (3) more on request
  (4) depending on residue vessel
  (5) Vacuum systems down to max. 1mbar possible
  (6) Process fluid H20 at 15°C at 50Hz
  (7) bei max. 15°C


As the units are built according to your wishes the technical spesifications are to be regarded as an orientation. Errors, changes and omissions excepted.