Units for solvent recycling
Technical data and product range
Each unit is developed, planned, constructed and installed acording to your wishes and requirements.
Prices are available on request.
In our download-area you will find the brochure "Solvent recycling".
| Design model |
SRU-30 |
SRU-60 |
SRU-95 |
SRU-165 |
SRU-265 |
| Overall Capacity (l) |
30 |
60 |
95 |
165 |
265 |
Operating capacity
min.-max. (l) |
15-20 |
30-35 |
50-55 |
90-100 |
150-170 |
| Nominal distillation rate (l/h) (1) |
3-10 |
10-25 |
20-40 |
30-65 |
40-90 |
| Process pressure |
-1,0 to +0,5 bar |
| Process temperatur (2) |
max. 200 °C |
| Thermal oil heating |
integrated |
Protection
class  |
Ex II 1/2G EEx cdemn (ia/ib) IIA T3 |
Power consumption,
normal operation (kW) |
1,8 |
2,9 |
5,0 |
8,0 |
11,0 |
Power consumption,
heating (kW) |
3,0 |
5,0 |
7,5 |
10,0 |
18,0 |
| Voltage, frequency (3) |
400 V, 3 Ph, 50 Hz |
Cooling medium
requirements (m³) (7) |
0,6 |
0,7 |
0,9 |
1,0 |
1,2 |
| Width (mm) |
500 |
590 |
750 |
850 |
| Height (mm) (4) |
800-1620 |
1620-1650 |
1650-1800 |
| Depth (mm) |
1200 |
1500 |
1800 |
2000 |
| Net weight approx. (kg) |
180 |
280 |
380 |
420 |
540 |
| Integrated vacuum units |
DT-6 |
DT-10 |
DT-30 |
Vacuum pressure
max. (mbar) (5) |
60 |
60 |
40 |
| Max. suction capacity m³/h (6) |
6 |
10 |
25 |
| Weight approx. (kg) |
40 |
50 |
65 |
(1) depending on solvent & degree of polution
(2) elevated temperature possible
(3) more on request
(4) depending on residue vessel
(5) Vacuum systems down to max. 1mbar possible
(6) Process fluid H20 at 15°C at 50Hz
(7) bei max. 15°C
| Design model |
SRU-450 |
SRU-650 |
SRU-1500 |
SRU-2000/
SRU-3000 |
| Overall Capacity (l) |
450 |
650 |
1500 |
2000/
3000 |
Operating capacity
min.-max. (l) |
250-350 |
350-450 |
1000-1200 |
1200-1500/ 1800-2200 |
| Nominal distillation rate (l/h) (1) |
60-160 |
80-200 |
200-500 |
300-600/
400-900 |
| Process pressure |
-1,0 to +0,5 bar |
| Process temperatur (2) |
max. 200 °C |
| Thermal oil heating |
integrated |
assimilable/ separate |
Protection class  |
Ex II 1/2G EEx cdemn (ia/ib) IIA T3 |
Power consumption,
normal operation (kW) |
16,0 |
26,0 |
39,0 |
44/
55 |
Power consumption,
heating (kW) |
30 |
40 |
70 |
80/
100 |
| Voltage, frequency (3) |
400 V, 3 Ph, 50 Hz |
Cooling medium
requirements (m³) (7) |
1,5 |
1,5 |
2,0 |
2,2/ 2,5 |
| Width (mm) |
2400 |
2800 |
2800 |
2800/
3200 |
| Height (mm) (4) |
2800-3000 |
3250-3400 |
3800-4000 |
4000-4200/ 4600-4800 |
| Depth (mm) |
1600 |
1700 |
1700/
2000 |
| Net weight approx. (kg) |
1100 |
1300 |
1600 |
1800/
2100 |
| Integrated vacuum units |
DT-50 |
DT-95 |
DT-110/
DT-130 |
Vacuum pressure
max. (mbar) (5) |
40 |
| Max. suction capacity m³/h (6) |
50 |
80 |
100/
110 |
| Weight approx. (kg) |
100 |
140 |
165/
180 |
(1) depending on solvent & degree of polution
(2) elevated temperature possible
(3) more on request
(4) depending on residue vessel
(5) Vacuum systems down to max. 1mbar possible
(6) Process fluid H20 at 15°C at 50Hz
(7) bei max. 15°C
As the units are built according to your wishes the technical spesifications