Technical data and product range: DesbaTec solvent recycling units
The technical data of our vacuum distillation units in overview.
Every DesbaTec unit is developed, planned, constructed and setup according to your wishes and requirements.
Prices are available on request.
In our download-area you will find the brochure "Solvent recycling"
Model | SRU-30 | SRU-60 | SRU-95 | SRU-165 | SRU-265 |
---|---|---|---|---|---|
Overall capacity (l) | 30 | 60 | 95 | 165 | 265 |
Operating capacity min.-max (l) | 15-20 | 30-35 | 45-55 | 80-90 | 130-140 |
Nominal distillation rate (l/h)(1) | 3-10 | 10-25 | 20-35 | 25-50 | 40-70 |
Process pressure (bar) | -1,0 to +0,5 | ||||
Process temperature (°C)(2) | 200° | ||||
Thermo oil heating | integrated | ||||
-Protection class with inerting and suction | EX II 3 G c IIA T3 | ||||
Power consumption normal operation ca. (kW) | 1,8 | 2,9 | 3,5 | 6,0 | 7,5 |
Power consumption heating (kW) | 3,0 | 5,0 | 5,0 | 7,5 | 10 |
Voltage, fequency(3) | 230/ 400V, 3 Ph, 50 Hz | ||||
Coolant requirements (m³)(7) | 0,6 | 0,7 | 0,9 | 1,0 | 1,2 |
Width (mm) | 590 | 590 | 590 | 750 | 850 |
Height (mm)(4) | 800-1620 | 1620-1650 | 1620-1800 | ||
Depth (mm) | 1200 | 1500 | 1800 | 2000 | 2000 |
Net weight approx. (kg) | 180 | 280 | 380 | 420 | 540 |
Related vacuum units | DT-6 | DT-10 | DT-30 | ||
Vacuum pressure max. (mbar)(5) | 35 | 35 | 35 | ||
Max. suction capacity m³/h(6) | 6 | 10 | 30 | ||
Weight approx. (kg) | 30 | 30 | 65 |
Modell | SRU-320 | SRU-450 | SRU-650 | SRU-1500 | SRU-2000 | SRU-3000 |
---|---|---|---|---|---|---|
Overall capacity (l) | 320 | 450 | 650 | 1500 | 2000 | 3000 |
Operating capacity min.-max (l) | 150-180 | 250-300 | 350-450 | 1000-1200 | 1200-1500 | 1800-2000 |
Nominal distillation rate (l/h)(1) | 50-80 | 70-130 | 80-160 | 200-500 | 300-600 | 400-900 |
Process pressure (bar) | -1,0 to +0,5 | |||||
Process temperature max. (°C)(2) | 200° | |||||
Thermo oil heating | integrated | separate(8) | ||||
-Protection class (with inerting and suction) | EX II 3 G c IIA T3 | |||||
Power consumption normal operation (kW) | 12 | 15 | 21 | 35 | 50 | 65 |
Power consumption heating (kW) | 15 | 20 | 30 | 50 | 60 | 80 |
Voltage, fequency(3) | 230/ 400 V, 3 Ph, 50 Hz | |||||
Coolant requirements (m³)(7) | 1,8 | 1,8 | 2,0 | 2,5 | 3,0 | 3,5 |
Width (mm) | 1250 | 2400 | 2800 | 2800 | 2800 | 3200 |
Height (mm)(4) | 1400-2750 | 2800-3000 | 3250-3400 | 3800-4000 | 4000-4200 | 4600-4800 |
Depth (mm) | 1750 | 1800 | 1800 | 1800 | 1800 | 2000 |
Net weight approx. (kg) | 700 | 1000 | 1200 | 1600 | 1800 | 2300 |
Related vacuum units | DT-30 | DT-50 | DT-95 | DT-110 | DT130 | |
Vacuum pressure max. (mbar)(5) | 35 | 35 | 35 | 35 | 35 | |
Max. suction capacity m³/h(6) | 25 | 50 | 80 | 100 | 110 | |
Weight approx. (kg) | 65 | 100 | 140 | 165 | 180 |
(1) dependent on solvent, operating conditions, level of contamination and water content, (2) higher temperatures possible, (3) further on request, (4) depending on residue container, (5) vacuum systems for max. pressure 1mbar possible, (6) process liquid H2O at 15°C at 50Hz, (7) at max. 15°C, (8) integratable on request
The technical data stated above are to be regarded as orientation, as every unit is built and developed according to your wishes and requirements. Changes, errors and omissions excepted. Photos and images can differ from actual quotation.